Summary for Test 2018-07-02-17-4
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 212830 DEA: 080R3504 EFIS: 0812000071 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-111-10-R16.1-111-R60.5 |
Award Date | 01/29/2018 |
Closeout Date | 12/12/2019 |
Work Description | FRP COMPOSITE SYSTEM FOR COLUMNS. HINGES RESTRAINERS ON THE DECKS |
Location Description | RIVERSIDE COUNTY IN BANNING AND PALM SPRING AT SAN GORGONIO WASH BRIDGE AND AT WHITEWATER RIVER OVERFLOW BRIDGE |
QA Service Level | 1 (Verified on 03/01/2018) |
Sample Information
Sample Taken Date | 07/02/2018 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2018 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Gr 55 Bolts |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | C874451 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S43-015-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 428917 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Gr 55 | |
Bolt Length(s) | 18.5 20.5 | Nut Specification | A563 |
Washer Specification | NA | Finish | HDG |
Diameter/Size | .75 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-07-02-17
DIME Test ID: 2018-07-02-17-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-08-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/25/2018
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1E | F 1554 Gr 55 Bolt, 10 Degree Wedge | 0.334 | 31427 | 139 | 94093 | 72874 | 24340 | F 1554 Gr 55 Bolt |
General comments (publicly viewable) (Max 1000 characters): F 1554 Gr 55 Bolt
Test Graph
Source: Partner Data Point FileTest was verified on 7/31/2018 ✔