Summary for Test 2018-07-02-17-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212830 DEA: 080R3504 EFIS: 0812000071 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-111-10-R16.1-111-R60.5 |
| Award Date | 01/29/2018 |
| Closeout Date | 12/12/2019 |
| Work Description | FRP COMPOSITE SYSTEM FOR COLUMNS. HINGES RESTRAINERS ON THE DECKS |
| Location Description | RIVERSIDE COUNTY IN BANNING AND PALM SPRING AT SAN GORGONIO WASH BRIDGE AND AT WHITEWATER RIVER OVERFLOW BRIDGE |
| QA Service Level | 1 (Verified on 03/01/2018) |
Sample Information
| Sample Taken Date | 07/02/2018 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2018 |
| Sample type | Quality Assurance | A brief description of the sample | F1554 Gr 55 Bolts |
| The quantity of what the sample constitutes | 5 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | C874451 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S43-015-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 428917 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Gr 55 | |
| Bolt Length(s) | 18.5 20.5 | Nut Specification | A563 |
| Washer Specification | NA | Finish | HDG |
| Diameter/Size | .75 | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-07-02-17
DIME Test ID: 2018-07-02-17-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-08-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/25/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 28099-6214616302 | ?\" | 50724 | 225.63 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 7/31/2018 ✔