Summary for Test 2018-07-10-8-1
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 213491 DEA: 031H6104 EFIS: 0316000190 |
|---|---|
| DIST-CO-RTE-PM | 03--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | METS is performing preliminary field investigation and testing to help design choose a retrofitting plan for the Sacramento West End Viaduct. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/22/2019) |
Sample Information
| Sample Taken Date | 07/10/2018 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Check Sample Plates |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joshua | Last name of sampler or witnessed by | Moore |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | C740528 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Steel Check Sample Plate | Heat Number(s) | Unknown |
|---|---|---|---|
| Material Specification | A36 | Grade | Unknown |
| Thickness | 0.3125 | Shape | Rectangle |
| Metal Foundry Manufacturer (Mill) | Unkown | Plate Dimension | 8.250" x 3.250" |
Test Details
DIME Sample ID: 2018-07-10-8
DIME Test ID: 2018-07-10-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Test Release Date: 2018-08-01
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Brian
Date of test: 07/25/2018
UTM: 67KIP
Temperature: 72 F
| Num | Sample | Heat Number | Width (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Total Elongation (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | N/A | 0.501 | 0.1493 | 43117 | 65559 | 30.8 | Brian | |
| 2 | N/A | 0.506 | 0.1498 | 42481 | 66088 | 34.9 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 7/25/2018 ✔