Summary for Test 2018-07-12-4-3

Test performed: ASTM C109-11

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/12/2018 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing07/12/2018 Sample typeProficiency
A brief description of the sampleCCRL 209 The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationCM188209
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCCRL
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2018-07-12-4
DIME Test ID: 2018-07-12-4-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2019-02-20

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: Stephen Donnelly
Date of test: 07/23/2018
Age of specimen: 7 days
The amount of flow (In percent): 117 %
The amount of water used (In percent): 359 %
Maximum load of 1st specimen (lb): 15094 lb
Maximum load of 2nd specimen (lb): 16080 lb
Maximum load of 3rd specimen (lb): 16579 lb
Cross sectional area loaded of 1st specimen (sq. inch): 4 in^2
Cross sectional area loaded of 2nd specimen (sq. inch): 4 in^2
Cross sectional area loaded of 3rd specimen (sq. inch): 4 in^2
Compressive strength of 1st specimen (psi): 3773.5 psi
Compressive strength of 2nd specimen (psi): 4020 psi
Compressive strength of 3rd specimen (psi): 4144.75 psi
Average Compressive strength (to nearest 10 psi): 3980 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/13/2019