Summary for Test 2018-07-12-2-9

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212376
DEA: 044G8504
EFIS: 0413000052
DIST-CO-RTE-PM04-SM-1-R44.1
Award Date04/12/2018
Closeout Date09/01/2020
Work DescriptionREPLACE PEDESTRIAN OVERCROSSING
Location DescriptionSAN MATEO COUNTY IN PACIFICA AT THE SAN JOSE AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 05/23/2018)

Sample Information

Sample Taken Date07/12/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing07/19/2018 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes6 lots
From where was the sample collectedFabricator First name of sampler or witnessed bygreg
Last name of sampler or witnessed byjohnston Title of samplerQA
Telephone number of sampler9165247768 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGerdau
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL53-043-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)65031208
Hoop Manufacturer Lot Number(s)1,6 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyGerdau Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-07-12-2
DIME Test ID: 2018-07-12-2-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-07-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/20/2018
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
124#6/19mm0.4445165102650necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/20/2018 ✔