Summary for Test 2018-06-20-12-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date06/20/2018 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing07/03/2018 Sample typeIndependent Assurance
A brief description of the sampleA325 Bolt, nut and washer The quantity of what the sample constitutes1 lot
From where was the sample collectedJob Site First name of sampler or witnessed byRussell
Last name of sampler or witnessed byLynch Title of samplerIQA Inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameLeJeune Bolt Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL96-077-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)28056-10537450-Caltrans
Heat Number(s)10537450, 6214552205, 174316 Nut Mfg. Lot Number(s)28125-6214552205
Washer Mfg. Lot Number(s)d4996 Bolt SpecificationA325
Bolt Length(s) Nut SpecificationA563 DH
Washer SpecificationF436 FinishMech Galv
Diameter/Size1" x 3-1/2" Bolt Mfg. Lot Number28056-10537450
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2018-06-20-12
DIME Test ID: 2018-06-20-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-08-08

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/19/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
112A28056-105374501\"93398415.510A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 8/1/2018 ✔