Summary for Test 2018-05-13-5-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 212574
DEA: 02368414
EFIS: 0215000066
DIST-CO-RTE-PM02-SHA-44-R4.6/R6.4
Award Date10/13/2017
Closeout Date11/24/2021
Work DescriptionCONSTRUCT OVERCROSSING, WIDEN WITH HMA AND AB, AND OVERLAY WITH HMA
Location DescriptionSHASTA COUNTY NEAR PALO CEDRO FROM CLOUGH CREEK BRIDGE TO 0.6 MILE WEST OF DESCHUTES ROAD UNDERCROSSING
QA Service Level1 (Verified on 07/28/2017)

Sample Information

Sample Taken Date05/13/2018 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing05/14/2018 Sample typeVerification
A brief description of the sample1/2-inch Type A HMA, PG 64-16 The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byAnthony
Last name of sampler or witnessed byOrtiz Title of samplerTester
Telephone number of samplerUnknown Laboratory sample identificationD77367
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTullis, Inc - Northstate Asphalt - Redding, CA
Transportation Laboratory (TL) Number896273 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set HMA PayNo

Test Details

DIME Sample ID: 2018-05-13-5
DIME Test ID: 2018-05-13-5-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2018-07-16

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Colt Sweeny
Date of test: 05/15/2018
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.00 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/16/2018 ✔