Summary for Test 2018-07-02-6-1
Test performed: ASTM A775-07b-re14Project Information
| Project Identifiers | Project ID: 212741 DEA: 020E1804 EFIS: 0200000022 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-29.8/30.2 |
| Award Date | 12/13/2017 |
| Closeout Date | 12/17/2021 |
| Work Description | BRIDGE REPLACEMENT |
| Location Description | PLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY |
| QA Service Level | 1 (Verified on 12/06/2017) |
Sample Information
| Sample Taken Date | 07/02/2018 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2018 |
| Sample type | Department Acceptance | A brief description of the sample | Epoxy coated rebar |
| The quantity of what the sample constitutes | 1 lot each heat | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
| Title of sampler | QAI | Telephone number of sampler | 5624806984 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | CMC Brighton CO | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-047-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4 - 4074536 4 - 4074534 5 - 4075961 5 - 4075962 5 - 4077349 5 - 4077380 5 - 4077379 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | UD76932NA | Rebar Coating Specification | ASTM A775 |
| Rebar Size (#) | 4 and 5 | Rebar Coating Color | Green |
| Rebar Manufacturer | CMC (Commercial Metals Company) | Rebar Coater | CMC Brighton CO |
| Rebar Powder Manufacturer | AkzoNobel Surface Chemistry, LLC | Release Number | N/A |
| Quality Assurance Code | N/A |
Test Details
DIME Sample ID: 2018-07-02-6
DIME Test ID: 2018-07-02-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2018-07-20
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 07/13/2018
Lower spec. limit LSL: 7
Upper spec. limit USL: 12
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 7.43
First Bar Side 2 mean value: 6.81
Second Bar Side 1 mean value: 7.02
Second Bar Side 2 mean value: 7.12
First Bar Mean: 7.12
Second Bar Mean: 7.07
Total mean value: 7.1
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/13/2018 ✔