Summary for Test 2018-04-09-15-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 212886 DEA: 023H1204 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-5-R0.0/R22.4 |
| Award Date | 01/03/2018 |
| Closeout Date | 02/06/2019 |
| Work Description | COLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR |
| Location Description | TEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 04/09/2018 | Sample Unique Key | 15 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/10/2018 | Sample type | Verification |
| A brief description of the sample | Combined RAP | The quantity of what the sample constitutes | JMF Renewal |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Michael |
| Last name of sampler or witnessed by | Allegretto | Title of sampler | Tech |
| Telephone number of sampler | Unknown | Laboratory sample identification | D77319B |
| Linked DIME Sample ID | 2018-04-09-11 | The fabricator/manufacturer/facility name | Tullis, Inc - Northstate Asphalt - Redding, CA |
| Transportation Laboratory (TL) Number | 852096 | Inspector Lot Number from the Transportation Laboratory (TL) Form | 1-5 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt |
|---|---|---|---|
| Aggregate Size | Combined 1/2-inch | Aggregate Source | Unknown |
| RAP Stockpile | Static | Stockpile Size (tons) | Unknown |
| Reclaimed Asphalt Pavement Mix Number | Not set | HMA Pay | No |
Test Details
DIME Sample ID: 2018-04-09-15
DIME Test ID: 2018-04-09-15-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2018-07-12
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Colt Sweeny
Date of test: 04/11/2018
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 6.29 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/12/2018 ✔