Summary for Test 2018-07-05-8-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212681 DEA: 024G2404 EFIS: 0213000095 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-5-R25.2 |
| Award Date | 11/16/2017 |
| Closeout Date | 10/05/2021 |
| Work Description | STRENGTHEN AND UPGRADE BRIDGES. |
| Location Description | SISKIYOU COUNTY ABOUT 5 MILES NORTH OF WEED AT THE NORTH EDGEWOOD OVERHEAD |
| QA Service Level | 1 (Verified on 03/21/2018) |
Sample Information
| Sample Taken Date | 07/05/2018 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/11/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Bar Lock Standard Couplers |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Russel | Last name of sampler or witnessed by | Cox |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Dayton Superior | Transportation Laboratory (TL) Number | C980903 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | NA |
| Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | 8 | Coupler Model | Bar Lock |
| Coating Standards | ASTM A775 | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | A152317 A150815 | Rebar Heat Number(s) | NA |
| Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-07-05-8
DIME Test ID: 2018-07-05-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-07-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/11/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 1 | #8/25mm | 0.79 | 0 | 76905 | 97348 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/11/2018 ✔