Summary for Test 2018-05-14-26-6

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 212680
DEA: 024F5504
EFIS: 0213000005
DIST-CO-RTE-PM02-SIS-89-20.9 - 21.2
Award Date11/14/2017
Closeout Date05/15/2019
Work DescriptionBRIDGE REPLACEMENT WITH PRE-CAST I-GIRDER AND RECONSTRUCT HIGHWAY
Location DescriptionSISKIYOU COUNTY NEAR MCCLOUD FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF MUD CREEK BRIDGE
QA Service Level1 (Verified on 02/12/2018)

Sample Information

Sample Taken Date05/14/2018 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2018
Sample typeVerification A brief description of the sample1/2-inch Type A HMA, PG 64-28 PM
The quantity of what the sample constitutesJMF Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byAllegretto
Title of samplerPEI Telephone number of samplerUnknown
Laboratory sample identificationD77365 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTullis, Northstate Asphalt, Redding, CA Transportation Laboratory (TL) Number853534
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-14-26
DIME Test ID: 2018-05-14-26-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2018-07-10

Test Results


Input Type: Calculated
Tester's full name: Dennis Hickey
Date of test: 05/16/2018
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): no data
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): no data
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): no data
Stripping Inflection Point (Wheel A): >25000
Stripping Inflection Point (Wheel B): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/10/2018