Summary for Test 2018-06-24-1-4
Test performed: ASTM A934-13Project Information
Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
---|---|
DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
Award Date | 11/16/2017 |
Closeout Date | 12/08/2022 |
Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
Sample Taken Date | 06/24/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2018 |
Sample type | Quality Assurance | A brief description of the sample | No. 9 Grade 75 epoxy coated bars, and hex nuts |
The quantity of what the sample constitutes | 100 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Williams Form | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-162-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | 9 |
Nut Specification for Threaded Bar | ASTM A108 | System Manufacturer | Williams Form Eng |
Epoxy Coating Color | Purple | Threaded Bar Application | Threaded Bar |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100792512,100792511,100891184,100888818 |
Nut Heat Number(s) | 8296508 | Bar Lot Number | 10079251121,10089118420,10088881821,100792512 |
Nut Lot Number | 9J1D | Coupler Heat Number(s) | |
Coupler Grade |
Test Details
DIME Sample ID: 2018-06-24-1
DIME Test ID: 2018-06-24-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-07-18
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 07/10/2018
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: 100891184-4 A
Bar # for Second Bar: 100891184-4B
First Bar Side 1 mean value: 11.23
First Bar Side 2 mean value: 9.75
Second Bar Side 1 mean value: 11.69
Second Bar Side 2 mean value: 9.94
First Bar Mean: 10.49
Second Bar Mean: 10.82
Total mean value: 10.65
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/11/2018 ✔