Summary for Test 2018-06-18-3-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210490 Permit Numbers: 0711NMC1061 0713NRT1641 0716NRT0073 0716NRT2321 0717NRT2707 0717NRT2428 0717NRT0600 0716NRT1660 0716NRT0559 0714NRW0422 0714NRW0753 0715NRT1289 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-30.1/30.1 |
| Award Date | 10/01/2011 |
| Closeout Date | 06/16/2021 |
| Work Description | Remove and replace the existing bridge railing along west edge of the structure with new 6' high ornamental railing; install streetlights; remove and replace the existing chainlink fence and gate at the south end of the bridge with new fence; install power conduits in the existing walkway along |
| Location Description | California Street OC, Ventura |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 06/18/2018 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/18/2018 |
| Sample type | Quality Assurance | A brief description of the sample | 5/8 3 1/4 |
| The quantity of what the sample constitutes | 49 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
| Title of sampler | QA Inspection | Telephone number of sampler | 6616185971 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | 2018-06-18-3 |
| The fabricator/manufacturer/facility name | Columbia Steel | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-036-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412638 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 25287-75065549 | |
| Washer Mfg. Lot Number(s) | D5605 | Bolt Specification | F3125 |
| Bolt Length(s) | 3 1/4" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Mechanically Galvanized |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 365609A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-06-18-3
DIME Test ID: 2018-06-18-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-07-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/05/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 25287-75065549 | 5/8\" | 34458 | 153.28 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 7/12/2018 ✔