Summary for Test 2018-06-06-8-1

Test performed: ASTM C496-17

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date06/06/2018 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing06/11/2018 Sample typeQuality Assurance
A brief description of the sampleconcrete cylinders The quantity of what the sample constitutes2 cylinders
From where was the sample collectedFabricator First name of sampler or witnessed bysherri
Last name of sampler or witnessed bybrannon Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility namePRE CAST
Transportation Laboratory (TL) NumberL48-035-18 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSFI-LWSBS5
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected5903361
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedFabricator Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-06-06-8
DIME Test ID: 2018-06-06-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C496-17: Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens (Split Tensile Strength)
Test Release Date: 2018-07-05

Test Results


Number of Specimens: 2
Input Type: Measured
Tester's full name: Larry McCrum
Date of test: 07/05/2018
Diameter (specimen 1): 6.03 in
Diameter (specimen 2): 6.03 in
Length (specimen 1): 12 in
Length (specimen 2): 11.99 in
Maximum applied load indicated by the testing machine (specimen 1): 31840 lbf
Maximum applied load indicated by the testing machine (specimen 2): 33760 lbf
Age (specimen 1): 29 days
Age (specimen 2): 29 days
Split Tensile Strength (specimen 1): 280 psi
Split Tensile Strength (specimen 2): 295 psi
Average Split Tensile Strength: 290 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/5/2018 ✔