Summary for Test 2018-06-25-2-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 212849
DEA: 073W5704
EFIS: 0716000336
DIST-CO-RTE-PM07-LA-210-R28.5/R30.8
Award Date01/03/2018
Closeout Date08/30/2019
Work DescriptionREPLACE BRIDGE APPROACH SLABS AND REHABILITATE DECKS.
Location DescriptionLOS ANGELES COUNTY IN PASADENA AND ARCADIA FROM SIERRA MADRE BOULEVARD UNDERCROSSING TO BALDWIN AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/02/2018)

Sample Information

Sample Taken Date06/25/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing06/25/2018 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes10 Tankers
From where was the sample collectedSource First name of sampler or witnessed byChris
Last name of sampler or witnessed byNunes Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameKwik bond and Reichhold
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1127054
Batch Number1127054 Mix number1127054

Test Details

DIME Sample ID: 2018-06-25-2
DIME Test ID: 2018-06-25-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2018-07-03

Test Results


Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 07/03/2018
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 106
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 56.9
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3006
Styrene ASTM D 2369 40% to 50 %: 46
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 545
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.4
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/3/2018 ✔