Summary for Test 2018-03-21-13-7

Test performed: ASTM C131-1

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date03/21/2018 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing03/29/2018 Sample typeQuality Control
A brief description of the sampleLightweight Aggregate The quantity of what the sample constitutes2 bags
From where was the sample collectedSource First name of sampler or witnessed byJohn
Last name of sampler or witnessed byDong Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identification18-0046
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameAssociated Signal Hill
Transportation Laboratory (TL) NumberC914206A Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)NA
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-03-21-13
DIME Test ID: 2018-03-21-13-7
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C131-1: Standard Test Method for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine
Test Release Date: 2018-07-02

Test Results


Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 07/02/2018
Aggregate Source: Signal Hill
Aggregate Type: 9.5 coarse Hydrolite
Aggregate Maximum Nominal Size: 12.5
Grading designation used?: C
Percent loss by mass due to abrasion and impact: 39 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2018 ✔