Summary for Test 2018-06-25-1-2

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 211777
DEA: 04209504
EFIS: 0412000116
DIST-CO-RTE-PM04-MRN,SON-1-50.2/50.5,0.0/0.2
Award Date01/04/2017
Closeout Date10/21/2019
Work DescriptionREPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121
Location DescriptionMARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE
QA Service Level1 (Verified on 01/17/2017)

Sample Information

Sample Taken Date06/25/2018 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing06/25/2018 Sample typeQuality Assurance
A brief description of the sample1 A722 Thread Bar The quantity of what the sample constitutes2
From where was the sample collectedSource First name of sampler or witnessed byTory
Last name of sampler or witnessed byMcLaurin Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameDSI
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL67-043-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size8
Nut Specification for Threaded Barxxx System ManufacturerDSI
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)6214608004
Nut Heat Number(s)74105860 Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-06-25-1
DIME Test ID: 2018-06-25-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-07-03

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/26/2018
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
12A722 DSI 1\" Threaded Bar & Nut Bar #6214608004, Nut #741058600.85157861136611100A722 Bar & NutFred

General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/26/2018 ✔