Summary for Test 2018-06-25-1-2
Test performed: ASTM A722-15Project Information
Project Identifiers | Project ID: 211777 DEA: 04209504 EFIS: 0412000116 |
---|---|
DIST-CO-RTE-PM | 04-MRN,SON-1-50.2/50.5,0.0/0.2 |
Award Date | 01/04/2017 |
Closeout Date | 10/21/2019 |
Work Description | REPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121 |
Location Description | MARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE |
QA Service Level | 1 (Verified on 01/17/2017) |
Sample Information
Sample Taken Date | 06/25/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/25/2018 |
Sample type | Quality Assurance | A brief description of the sample | 1 A722 Thread Bar |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | DSI | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-043-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Deformed | Rebar Size | 8 |
Nut Specification for Threaded Bar | xxx | System Manufacturer | DSI |
Epoxy Coating Color | NA | Threaded Bar Application | |
Coating Standards | Uncoated | Bar Heat Number(s) | 6214608004 |
Nut Heat Number(s) | 74105860 | Bar Lot Number | Unknown |
Nut Lot Number | Unknown | Coupler Heat Number(s) | Unknown |
Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2018-06-25-1
DIME Test ID: 2018-06-25-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-07-03
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/26/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | A722 DSI 1\" Threaded Bar & Nut | Bar #6214608004, Nut #74105860 | 0.85 | 157861 | 136611 | 10 | 0 | A722 Bar & Nut | Fred |
General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/26/2018 ✔