Summary for Test 2026-11-16-11-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 6666690
DEA: 081W1704
EFIS: 0827000043
DIST-CO-RTE-PM08-SBD-62-50/61
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/16/2026 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing11/18/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
Sample size From where was the sample collectedSource
First name of sampler or witnessed byDylan Last name of sampler or witnessed byNault
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGrante-Desert Hot Spring Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-11-16-11
DIME Test ID: 2026-11-16-11-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-11-25

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 11/23/2026
Time of test: 8:21 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 75.1 %
Viscosity reading #1 (A) : 0.374 Pa-s
Viscosity reading #2 (B) : 0.376 Pa-s
Viscosity reading #3 (C): 0.377 Pa-s
Average viscosity: 0.376 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/25/2026 ✔