Summary for Test 2026-11-03-24-2
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/03/2026 | Sample Unique Key | 24 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/09/2026 | Sample type | JMF Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1can |
| Sample size | From where was the sample collected | Source | |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | MCPHERSON |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | RJ Noble-Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | n/a | |
| Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | n/a | HMA Supplier Mix ID Number | n/a |
Test Details
DIME Sample ID: 2026-11-03-24
DIME Test ID: 2026-11-03-24-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-11-12
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 11/10/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 202.389 grams
Mass of container #2 before test (m2i): 207.972 grams
Mass of container #1 after test (m1f): 202.356 grams
Mass of container #2 after test (m2f): 207.940 grams
Mass of empty container #1: 167.467 grams
Mass of empty container #2: 172.825 grams
Mass correction factor: 0.006
Average mass change: -0.087 percent
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/12/2026 ✔