Summary for Test 2018-06-12-1-1
Test performed: ASTM A615-15Project Information
| Project Identifiers | Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-37.2/42.4 |
| Award Date | 11/16/2015 |
| Closeout Date | 07/11/2022 |
| Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
| Location Description | IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA |
| QA Service Level | 1 (Verified on 03/07/2016) |
Sample Information
| Sample Taken Date | 06/12/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/14/2018 |
| Sample type | Quality Assurance | A brief description of the sample | A615 Grade 75 Threaded Bar |
| The quantity of what the sample constitutes | Unknown | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | QA Inspector | Telephone number of sampler | 510-693-3545 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | DSI Gerdau | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-030-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Plain | Rebar Size | #8 |
| Nut Specification for Threaded Bar | A519 | System Manufacturer | DSI |
| Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
| Coating Standards | Uncoated | Bar Heat Number(s) | 6214549206 |
| Nut Heat Number(s) | 00A172983 | Bar Lot Number | 2161-2104 |
| Nut Lot Number | 082369 | Coupler Heat Number(s) | n/a |
| Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2018-06-12-1
DIME Test ID: 2018-06-12-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-06-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/15/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | #8 Bar Heat #6214549206, Nut Heat #00A172983 | L02-030-18 | 0.79 | 113819 | 87133 | 0 | A615 Threaded Bar and Nut | Brian |
General comments (publicly viewable) (Max 1000 characters): A615 Threaded Bar and Nut
Test Graph
Source: Partner Data Point FileTest was verified on 6/19/2018 ✔