Summary for Test 2026-08-06-35-3

Test performed: ASTM E23-18

Project Information

Project IdentifiersProject ID: 994675
DEA: 07390204
EFIS: 0722000334
DIST-CO-RTE-PM07-LA-47-0.4 / 2.1
Award Date01/24/2025
Closeout DateNot set
Work DescriptionBridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location DescriptionRTE 47 between Terminal Island and San Pedro PM 0.4/2.1
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date08/06/2026 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing08/14/2026 Sample typeVerification
A brief description of the sampleASTM A709 QST W Shape W18x76x12 The quantity of what the sample constitutesStringer Beam Heat Number
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameFought & Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)625719
Material SpecificationA709 GradeQST 65
Thickness0 ShapeW
Metal Foundry Manufacturer (Mill)Nucor Yamato Steel Co Plate DimensionNA

Test Details

DIME Sample ID: 2026-08-06-35
DIME Test ID: 2026-08-06-35-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-18: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2026-10-27

Test Results


Input Type: Measured
Tester's full name: Steven Paine
Date of test: 10/27/2026
Temperature Required: 20 oF
Minimum Energy Required: 20 ftlb
Test Temperature 1: 20 oF
Impact Energy 1: 152 ftlb
Impact Energy 2: 148 ftlb
Impact Energy 3: 140 ftlb
Striker Radius: 8
Average Impact Energy: 147 ftlb
Value Exceeds The Machine Capacity?: No
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/27/2026 ✔