Summary for Test 2018-06-04-7-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212743 DEA: 030H26U4 EFIS: 0317000247 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-65-R5.0/R6.6 |
| Award Date | 02/14/2018 |
| Closeout Date | 10/21/2022 |
| Work Description | NORTHBOUND WIDENING AND RAMP IMPROVEMENTS. |
| Location Description | PLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 12/18/2017) |
Sample Information
| Sample Taken Date | 06/04/2018 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Size 14 HRC couplers CIDH lot 1 |
| The quantity of what the sample constitutes | 150 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jimmer | Last name of sampler or witnessed by | Ross |
| Title of sampler | SR | Telephone number of sampler | (510) 701-4595 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | HRC | Transportation Laboratory (TL) Number | C710751 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | 14 | Coupler Model | 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | CIDH Lot 1 75069594, 74106235 | Rebar Heat Number(s) | 6502379302 |
| Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-06-04-7
DIME Test ID: 2018-06-04-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-06-14
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/06/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | C1DH-1 | #14/43mm | 2.25 | 0 | 203125 | 90278 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/7/2018 ✔