Summary for Test 2026-09-15-91-3
Test performed: ASTM D5329-20Project Information
| Project Identifiers | Project ID: 1002671 DEA: 09402704 EFIS: 0924000060 |
|---|---|
| DIST-CO-RTE-PM | 09-MNO--unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/15/2026 | Sample Unique Key | 91 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/09/2026 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | J.H-HOT PLANT OPERATOR |
| Last name of sampler or witnessed by | J.H-HOT PLANT OPERATOR | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | HOT PLANT | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 58-22 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2026-09-15-91
DIME Test ID: 2026-09-15-91-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2026-10-22
Test Results
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 10/22/2026
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 51 mm
Ball Penetration (P2): 2 mm
Final Dial reading (F2): 52 mm
Ball Penetration (P3): 1 mm
Final Dial reading (F3): 50 mm
Resilience 1: 50 %
Resilience 2: 50 %
Resilience 3: 51 %
Average Resilience: 50 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/22/2026 ✔