Summary for Test 2026-05-22-73-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 215365 DEA: 120Q9704 EFIS: 1218000010 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-0/11.4 |
| Award Date | 07/27/2023 |
| Closeout Date | Not set |
| Work Description | I-405 improvement project from I-5 to Harbor Boulevard including extend pavement life, improve safety, enhance traffic operation, and incorporate Intelligent Transportation Systems (ITS). |
| Location Description | Orange County I-405 PM 0 - 11.4 |
| QA Service Level | 1 (Verified on 07/01/2021) |
Sample Information
| Sample Taken Date | 05/22/2026 | Sample Unique Key | 73 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/23/2026 | Sample type | Quality Control |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 1 per batch |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Ronald |
| Last name of sampler or witnessed by | Hernandez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Robertsons - Santa Ana | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SC590B33 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 2015250 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Wrong Way Detection Poles, SB Sand Canyon Off Ramp | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-05-22-73
DIME Test ID: 2026-05-22-73-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-10-15
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Yvan Lopez
Date of test: 06/19/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 120970 lb
Maximum load on cylinder 2: 119120 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4250 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/15/2026 ✔