Summary for Test 2026-09-25-46-9
Test performed: AASHTO T313-2025Project Information
| Project Identifiers | Project ID: 995353 DEA: 072XE504 EFIS: 0723000094 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-150-25.82/31 |
| Award Date | 01/26/2023 |
| Closeout Date | 06/09/2025 |
| Work Description | Remove the mud and the debris from the roadway and repair the eroded slopes and the slope drapery protection system, repair the damaged shoulder and AC dike in multiple locations, clean the drainage systems, repair the roadside signs and markers, and fix the compromised drainage systems |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/06/2023) |
Sample Information
| Sample Taken Date | 09/25/2026 | Sample Unique Key | 46 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/06/2026 | Sample type | Verification |
| A brief description of the sample | Asphalt Binder Sample | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Christian |
| Last name of sampler or witnessed by | christian Vulcan QC | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan-Sun Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | n/a | |
| Certified Asphalt Supplier | Valero Wilmington Refinery - Wilmington CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | n/a | HMA Supplier Mix ID Number | n/a |
Test Details
DIME Sample ID: 2026-09-25-46
DIME Test ID: 2026-09-25-46-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2026-10-15
Test Results
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 10/14/2026
Paired test specimens performed?: no data
BBR Software for individual test specimens: no data
Maximum test bath temperature at 240 S: 0.0 C
Minimum test bath temperature at 240 S: 0.0 C
Time of test load application: no data
File name of test data: no data
Time test specimen in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficients and least square fit R² value: 0.000
Comments: no data
Regression coefficient a: 0.000
Regression coefficient b: 0.000
Regression coefficient c: 0.000
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Loading time 8.0 s: 0.0 s
Load at 8.0 s: 0.0 mN
Test specimen deflection 8.0 s: 0.000 µm
Measured Stiffness Modulus 8.0 s: 0.000 MPa
Estimated Stiffness Modulus 8.0 s: 0.000 MPa
Difference between stiffness moduli 8.0 s: 0.00 %
Estimated m-value 8.0 s: 0.000
Loading time 15.0 s: 0.0 s
Load at 15.0 s: 0.0 mN
Test specimen deflection 15.0 s: 0.000 µm
Measured Stiffness Modulus 15.0 s: 0.000 MPa
Estimated Stiffness Modulus 15.0 s: 0.000 MPa
Difference between stiffness moduli 15.0 s: 0.00 %
Estimated m-value 15.0 s: 0.000
Loading time 30.0 s: 0.0 s
Load at 30.0 s: 0.0 mN
Test specimen deflection 30.0 s: 0.000 µm
Measured Stiffness Modulus 30.0 s: 0.000 MPa
Estimated Stiffness Modulus 30.0 s: 0.000 MPa
Difference between stiffness moduli 30.0 s: 0.00 %
Estimated m-value 30.0 s: 0.000
Loading time 60.0 s: 0.0 s
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Test specimen deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 0.000 MPa
Estimated Stiffness Modulus 60.0 s: 86.241 MPa
Difference between stiffness moduli 60.0 s: 0.00 %
Estimated m-value 60.0 s: 0.445
Loading time 120.0 s: 0.0 s
Load at 120.0 s: 0.0 mN
Test specimen deflection 120.0 s: 0.000 µm
Measured Stiffness Modulus 120.0 s: 0.000 MPa
Estimated Stiffness Modulus 120.0 s: 0.000 MPa
Difference between stiffness moduli 120.0 s: 0.00 %
Estimated m-value 120.0 s: 0.000
Loading time 240.0 s: 0.0 s
Load at 240.0 s: 0.0 mN
Test specimen deflection 240.0 s: 0.000 µm
Measured Stiffness Modulus 240.0 s: 0.000 MPa
Estimated Stiffness Modulus 240.0 s: 0.000 MPa
Difference between stiffness moduli 240.0 s: 0.00 %
Estimated m-value 240.0 s: 0.000
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/15/2026 ✔