Summary for Test 2026-09-06-4-6
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/06/2026 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/18/2026 | Sample type | Verification |
| A brief description of the sample | Tank 10 | The quantity of what the sample constitutes | 2 of 2 cans |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Lisa |
| Last name of sampler or witnessed by | Dinh | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 090626-470 | |
| Linked DIME Sample ID | 2026-09-06-2 | The fabricator/manufacturer/facility name | Wilmington, CA |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Wilmington Refinery - Wilmington CA | Multigrade | Yes |
| Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | |
| HMA Type | HMA Supplier Mix ID Number |
Test Details
DIME Sample ID: 2026-09-06-4
DIME Test ID: 2026-09-06-4-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-10-14
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 10/14/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 211.602 grams
Mass of container #2 before test (m2i): 208.243 grams
Mass of container #1 after test (m1f): 211.433 grams
Mass of container #2 after test (m2f): 208.082 grams
Mass of empty container #1: 173.738 grams
Mass of empty container #2: 173.300 grams
Mass correction factor: 0.006
Average mass change: -0.448 percent
General comments (publicly viewable) (Max 1000 characters): RTFO
Test was verified on 10/14/2026 ✔