Summary for Test 2026-10-05-60-1
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1001609 DEA: 040AA244 EFIS: 0419000455 |
|---|---|
| DIST-CO-RTE-PM | 04-CC, -680-R0.0/R7.7 |
| Award Date | 12/18/2025 |
| Closeout Date | Not set |
| Work Description | INDIVIDUAL SLAB REPLACEMENT, COLD PLAN AC PVMT, GRIND EXIST CONC PVMT. |
| Location Description | CONTRA COSTA COUNTY IN SAN RAMON AND DANVILLE FROM THE ALAMEDA COUNTY LINE TO 0.2 MILE NORTH OF DIABLO ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/06/2025) |
Sample Information
| Sample Taken Date | 10/05/2026 | Sample Unique Key | 60 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/06/2026 | Sample type | Acceptance |
| A brief description of the sample | 1/2"RHMA-G | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Source | First name of sampler or witnessed by | Dennis |
| Last name of sampler or witnessed by | Yeung | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Pleasanton Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant Sampler | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-10-05-60
DIME Test ID: 2026-10-05-60-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-10-14
Test Results
How many times will the test be run?: Once
Input Type: Measured
Tester's full name: Dennis Yeung
Date of test: 10/07/2026
Clay reading: 5.4
Sand reading: 3.8
Sand Equivalent: 71
General comments (publicly viewable) (Max 1000 characters): Lot 1 SL. 3
Test was verified on 10/14/2026 ✔