Summary for Test 2026-09-15-72-8

Test performed: AASHTO T313-2025

Project Information

Project IdentifiersProject ID: 1001156
DEA: 081L9104
EFIS: 0821000038
COOP: 081734
DIST-CO-RTE-PM08-SBD-38-51.9
Award Date12/17/2024
Closeout DateNot set
Work DescriptionState Highway 38 at Stanfield Cutoff Roundabout
Location DescriptionIntersection of Stanfield Cutoff and State Highway 38 in the Big Bear area
QA Service Level2 (Verified on 04/07/2025)

Sample Information

Sample Taken Date09/15/2026 Sample Unique Key72
Date that the sample was received by the laboratory/organization performing the testing09/16/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byRobert
Last name of sampler or witnessed byJardine Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Oro Grande
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-09-15-72
DIME Test ID: 2026-09-15-72-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2026-10-13

Test Results


Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 10/12/2026
Paired test specimens performed?: no data
BBR Software for individual test specimens: no data
Maximum test bath temperature at 240 S: 0.0 C
Minimum test bath temperature at 240 S: 0.0 C
Time of test load application: no data
File name of test data: no data
Time test specimen in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficients and least square fit R² value: 0.000
Comments: no data
Regression coefficient a: 0.000
Regression coefficient b: 0.000
Regression coefficient c: 0.000
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Loading time 8.0 s: 0.0 s
Load at 8.0 s: 0.0 mN
Test specimen deflection 8.0 s: 0.000 µm
Measured Stiffness Modulus 8.0 s: 0.000 MPa
Estimated Stiffness Modulus 8.0 s: 0.000 MPa
Difference between stiffness moduli 8.0 s: 0.00 %
Estimated m-value 8.0 s: 0.000
Loading time 15.0 s: 0.0 s
Load at 15.0 s: 0.0 mN
Test specimen deflection 15.0 s: 0.000 µm
Measured Stiffness Modulus 15.0 s: 0.000 MPa
Estimated Stiffness Modulus 15.0 s: 0.000 MPa
Difference between stiffness moduli 15.0 s: 0.00 %
Estimated m-value 15.0 s: 0.000
Loading time 30.0 s: 0.0 s
Load at 30.0 s: 0.0 mN
Test specimen deflection 30.0 s: 0.000 µm
Measured Stiffness Modulus 30.0 s: 0.000 MPa
Estimated Stiffness Modulus 30.0 s: 0.000 MPa
Difference between stiffness moduli 30.0 s: 0.00 %
Estimated m-value 30.0 s: 0.000
Loading time 60.0 s: 0.0 s
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Test specimen deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 0.000 MPa
Estimated Stiffness Modulus 60.0 s: 285.139 MPa
Difference between stiffness moduli 60.0 s: 0.00 %
Estimated m-value 60.0 s: 0.319
Loading time 120.0 s: 0.0 s
Load at 120.0 s: 0.0 mN
Test specimen deflection 120.0 s: 0.000 µm
Measured Stiffness Modulus 120.0 s: 0.000 MPa
Estimated Stiffness Modulus 120.0 s: 0.000 MPa
Difference between stiffness moduli 120.0 s: 0.00 %
Estimated m-value 120.0 s: 0.000
Loading time 240.0 s: 0.0 s
Load at 240.0 s: 0.0 mN
Test specimen deflection 240.0 s: 0.000 µm
Measured Stiffness Modulus 240.0 s: 0.000 MPa
Estimated Stiffness Modulus 240.0 s: 0.000 MPa
Difference between stiffness moduli 240.0 s: 0.00 %
Estimated m-value 240.0 s: 0.000
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/13/2026 ✔