Summary for Test 2026-10-08-2-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 1002682
DEA: 112N2554
EFIS: 1125000084
DIST-CO-RTE-PM11-UNKNOWN--unknown
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 09/30/2026)

Sample Information

Sample Taken Date10/08/2026 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing05/18/2026 Sample typeQuality Assurance
A brief description of the sampleField Sample The quantity of what the sample constitutesField Sample
From where was the sample collectedSource First name of sampler or witnessed byFrancisco
Last name of sampler or witnessed byRuvalcaba Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVolumetric Truck
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sampleISR RSC
A detailed description of where the material sample was collectedField Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-10-08-2
DIME Test ID: 2026-10-08-2-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-10-12

Test Results


Number of specimens: 3
Input Type: Calculated
Tester's full name: Melchor Oronoz
Date of test: 10/12/2026
Correction factor: 1
Cylinder Age: 3 days
Break Description of Cylinder 1 (if not 'cone'): 2
Break Description of Cylinder 2 (if not 'cone'): 2
Break Description of Cylinder 3 (if not 'cone'): 2
Average Compressive Strength (to nearest 10): 6110 lb/in^2
Compressive Strength of Cylinder 1: 6229.57 lb/in^2
Compressive Strength of Cylinder 2: 5951.95 lb/in^2
Compressive Strength of Cylinder 3: 6142.91 lb/in^2
General comments (publicly viewable) (Max 1000 characters): 3 days - Complies. Tested 6110 psi avg. Min required is 4760 psi

Test was verified on 10/12/2026 ✔