Summary for Test 2026-09-24-52-3

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1002507
DEA: 081P5904
EFIS: 0824000006
DIST-CO-RTE-PM08-SBD-18-32.9/34.0
Award DateNot set
Closeout DateNot set
Work DescriptionRTE 18 GUARDRAIL / BARRIER UPGRADE (PM 32.9/34.0), SAN BERNARDINO. CONTRACT 08-1P5904, RE MARIN.
Location DescriptionNot set
QA Service Level1 (Verified on 09/01/2026)

Sample Information

Sample Taken Date09/24/2026 Sample Unique Key52
Date that the sample was received by the laboratory/organization performing the testing09/24/2026 Sample typeAcceptance
A brief description of the sample1"xNo.4, 3/8"xNo.8, & WCS Aggregate PCC The quantity of what the sample constitutes17 CY
From where was the sample collectedManufacturer First name of sampler or witnessed byIdris Najjar &
Last name of sampler or witnessed by& Robert Jarquin Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertson's Ready Mix — Lake Arrowhead
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0072
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt @ Robertson's Ready Mix, Lake Arrowhead
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberRRM09014

Test Details

DIME Sample ID: 2026-09-24-52
DIME Test ID: 2026-09-24-52-3
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-10-12

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Idris Najjar
Date of test: 09/25/2026
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
520 grams
0.0 grams100 %
14.0 grams97 %
98.0 grams81 %
204.0 grams61 %
325.0 grams38 %
427.0 grams18 %
475.0 grams9 %
479.8 grams8 %
498.4 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/12/2026 ✔