Summary for Test 2026-09-08-60-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1001308 DEA: 081L1804 EFIS: 0819000162 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-91-13.5/16.8 |
| Award Date | 10/20/2025 |
| Closeout Date | Not set |
| Work Description | JPCP (RSC), INDIVIDUAL SLAB REPLACEMENT (RSC) & RUBBERIZED HMA. |
| Location Description | RIVERSIDE COUNTY IN RIVERSIDE FROM 0.6 MILE WEST OF VAN BUREN BOULEVARD OVERCROSSING TO 0.2 MILE EAST OF MADISON STREET UNDERCROSSING. |
| QA Service Level | 1 (Verified on 06/24/2025) |
Sample Information
| Sample Taken Date | 09/08/2026 | Sample Unique Key | 60 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/18/2026 | Sample type | Acceptance |
| A brief description of the sample | 3/4" RWMA-G SP | The quantity of what the sample constitutes | 4 cores |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Christ |
| Last name of sampler or witnessed by | Caballero | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | L5SL1, L5SL2 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Materials Company — Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 226110 CORD SJR | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-08-60
DIME Test ID: 2026-09-08-60-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-10-12
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Robert Jarquin
Date of test: 09/23/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7399.9 grams
Mass of oven-dry sample in air for Sample 1: 2514.2 grams
Mass of container filled with the sample and water for Sample 1: 8871.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.411
Theoretical maximum density at 25°C (77°F): 150.1 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/12/2026 ✔