Summary for Test 2026-09-10-49-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001645
DEA: 051R1004
EFIS: 0523000125
DIST-CO-RTE-PM05-SLO, -1-32.6
Award DateNot set
Closeout DateNot set
Work DescriptionBRIDGE REPLACEMENT, HMA, AND RSP PROTECTION.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE
QA Service Level1 (Verified on 11/03/2025)

Sample Information

Sample Taken Date09/10/2026 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing09/10/2026 Sample typeQuality Assurance
A brief description of the sample4x8 Cylinders 752RN1810 The quantity of what the sample constitutes9/10/26 Pour - 752RN1810
From where was the sample collectedJob Site First name of sampler or witnessed byTim
Last name of sampler or witnessed byStover Title of samplerStructures Inspector
Telephone number of sampler Laboratory sample identification260910-1 752RN1810
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalPortland - San Luis Obispo
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name9/10/26 Pour
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number752RN1810
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-09-10-49
DIME Test ID: 2026-09-10-49-2
Testing Lab: CT D05 - Paso Robles Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-10-12

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 10/08/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 73384 lb
Maximum load on cylinder 2: 74373 lb
Maximum load on cylinder 3: 74398 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5838.0 psi
Compressive strength of cylinder 2: 5916.7 psi
Compressive strength of cylinder 3: 5918.7 psi
Compressive strength (to nearest 10 psi): 5890 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/12/2026 ✔