Summary for Test 2026-09-10-52-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000611
DEA: 120R32U4
EFIS: 1222000054
DIST-CO-RTE-PM12-ORA-55-0.2/R17.8
Award Date02/07/2025
Closeout DateNot set
Work DescriptionCOLD PLANE, PLACE RHMA, REPLACE CB, SIGNS AND MODIFY LIGHTING SYSTEM.
Location DescriptionORANGE COUNTY FROM 0.1 MILE SOUTH OF ROUTE 55/1 SEPARATION IN NEWPORT BEACH TO ROUTE 55/91 SEPARATION IN ANAHEIM
QA Service Level1 (Verified on 09/30/2024)

Sample Information

Sample Taken Date09/10/2026 Sample Unique Key52
Date that the sample was received by the laboratory/organization performing the testing09/18/2026 Sample typeVerification
A brief description of the sample1/2" RWMA O SP No LAS The quantity of what the sample constitutes2 Bags of Agg.
From where was the sample collectedManufacturer First name of sampler or witnessed byCuong
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification0569O-26
Linked DIME Sample ID The fabricator/manufacturer/facility nameR.J. Noble Company - Orange
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-09-10-52
DIME Test ID: 2026-09-10-52-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2026-10-12

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: DM
Date of test: 09/21/2026
Cumulative Percent Passing
100 %
100 %
100 %
100 %
98 %
87 %
34 %
16 %
10 %
8 %
6 %
4 %
3.2 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation.

Test was verified on 10/12/2026 ✔