Summary for Test 2026-06-09-66-5
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1001666 DEA: 051K4404 EFIS: 0518000208 |
|---|---|
| DIST-CO-RTE-PM | 05-MON,-101-R41.9/49.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | COLD PLANE, PLACE HMA & RHMA, LIGHTING AND INSTALL TMS ELEMENTS. |
| Location Description | MONTEREY COUNTY NEAR KING CITY FROM JOLON ROAD UNDERCROSSING TO 0.1 MILE NORTH OF LAGOMARSINO AVENUE |
| QA Service Level | 1 (Verified on 10/16/2025) |
Sample Information
| Sample Taken Date | 06/09/2026 | Sample Unique Key | 66 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/11/2026 | Sample type | Quality Control |
| A brief description of the sample | 4x8 Cylinders | The quantity of what the sample constitutes | 5 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | James |
| Last name of sampler or witnessed by | Watson | Title of sampler | QC Field Technician |
| Telephone number of sampler | Laboratory sample identification | 57S590 Set 2 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Graniterock - Salinas | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | Barrier Slab East side of RTE 101, STA 33+60 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 57S590 |
|---|---|---|---|
| The truck number from where the sample was collected | Load 13 | The batch plant ticket number from where the sample was collected | 0 |
| Concrete batch plant | Graniterock | The fabricator/manufacturer designation for the sample | Set 2 |
| A detailed description of where the material sample was collected | Barrier Slab East side of RTE 101, STA 33+60 | Where the material sample would have been placed if not sampled | |
| From Lot No. | 1 | Bag Lot No. | 1 |
Test Details
DIME Sample ID: 2026-06-09-66
DIME Test ID: 2026-06-09-66-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-10-08
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 06/16/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 55310 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 4400 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2026 ✔