Summary for Test 2026-10-06-21-1
Test performed: AASHTO T209-25Project Information
| Project Identifiers | Project ID: 1000970 DEA: 031J6304 EFIS: 0321000023 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-99-6.04/7.06 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | WILLOW SLOUGH REPLACEMENT |
| Location Description | SACRAMENTO COUNTY NEAR ELK GROVE FROM 0.2 MILE NORTH OF ARNO ROAD TO 0.4 MILE SOUTH OF DILLARD ROAD |
| QA Service Level | 1 (Verified on 02/13/2025) |
Sample Information
| Sample Taken Date | 10/06/2026 | Sample Unique Key | 21 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/07/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 RHMA | The quantity of what the sample constitutes | PSE |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Luis |
| Last name of sampler or witnessed by | Magana | Title of sampler | QA Tech |
| Telephone number of sampler | 2092250104 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Bradshaw Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 1556 |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-10-06-21
DIME Test ID: 2026-10-06-21-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-10-08
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: KHUE YANG
Date of test: 10/08/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7402.5 grams
Mass of oven-dry sample in air for Sample 1: 2502.6 grams
Mass of container filled with the sample and water for Sample 1: 8895.0 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.478
Theoretical maximum density at 25°C (77°F): 2471 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2026 ✔