Summary for Test 2026-09-22-8-6

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 993446
DEA: 120J34U4
EFIS: 1218000034
DIST-CO-RTE-PM12-ORA-55,55-29.6,R6.4/10.3
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION
QA Service Level1 (Verified on 06/24/2022)

Sample Information

Sample Taken Date09/22/2026 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing09/22/2026 Sample typeVerification
A brief description of the sample1/2" HMA-A R25 0.75% LAS The quantity of what the sample constitutes4 Bags of Agg, 2 Bags of Combined RAP
From where was the sample collectedManufacturer First name of sampler or witnessed byQC Vulcan
Last name of sampler or witnessed byQC Vulcan Title of sampler
Telephone number of sampler Laboratory sample identification0570A-26
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials - Irwnindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-09-22-8
DIME Test ID: 2026-09-22-8-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2026-10-09

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: David Padilla
Date of test: 09/26/2026
Bulk dry specific gravity: 2.608
Average uncompacted voids: 46.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/9/2026 ✔