Summary for Test 2026-09-30-53-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 1000510
DEA: 060W79U4
EFIS: 0622000189
DIST-CO-RTE-PM06-KER,TUL-99-56.4/57.6,0.0/13.5
Award Date04/10/2025
Closeout DateNot set
Work DescriptionRDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC.
Location DescriptionKERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING
QA Service Level1 (Verified on 08/26/2024)

Sample Information

Sample Taken Date09/30/2026 Sample Unique Key53
Date that the sample was received by the laboratory/organization performing the testing10/07/2026 Sample typeAcceptance
A brief description of the sampleCRCP The quantity of what the sample constitutes6 beams and 4 cylinder
From where was the sample collectedSource First name of sampler or witnessed byNeale
Last name of sampler or witnessed byBrown Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameonsite plant SPCI
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid Item3906202

Material Information

Material TypeConcrete The concrete mix design numberG3-26-PCC-400
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected7
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwith loader Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-09-30-53
DIME Test ID: 2026-09-30-53-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2026-10-07

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 10/07/2026
Identification number: 10
Width of specimen: 6.1 inch
Width of specimen 2: 6.0 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.2 inch
Depth of specimen 3: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 4910 lb
Maximum load applied 2: 6420 lb
Maximum load applied 3: 6030 lb
Curing history and apparent moisture condition of the specimen: Good
If specimen was capped, ground or if leather shims were used: leather shims were used
Defects in specimen: 0
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Modulus of rupture: 395 psi
Modulus of rupture 2: 510 psi
Modulus of rupture 3: 485 psi
Modulus of rupture average: 465 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0W79U4_37056_260930_7D_10pdf166.71 KB10/07/20262026-09-30-53-1   Info

Test was verified on 10/7/2026 ✔