Summary for Test 2026-07-13-84-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001169
DEA: 07314524
EFIS: 0722000300
COOP: 075283
DIST-CO-RTE-PM07---
Award Date07/03/2023
Closeout DateNot set
Work DescriptionI-105 METRO Express Lanes Project
Location DescriptionLA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6
QA Service Level2 (Verified on 04/11/2025)

Sample Information

Sample Taken Date07/13/2026 Sample Unique Key84
Date that the sample was received by the laboratory/organization performing the testing07/14/2026 Sample typeQuality Assurance
A brief description of the samplethree quarter inch HMA Type A The quantity of what the sample constitutes81.17 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byArroyo Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-07-13-84
DIME Test ID: 2026-07-13-84-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-10-07

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Aleksey Souglobov
Date of test: 07/17/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4004.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6169.6 g
Mass of HMA Sample prior to ignition: 2164.7 g
Mass Loss: 107.7 g
Mass of aggregate remaining after ignition: 2057.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.46 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.52 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/7/2026 ✔