Summary for Test 2026-07-13-84-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001169 DEA: 07314524 EFIS: 0722000300 COOP: 075283 |
|---|---|
| DIST-CO-RTE-PM | 07--- |
| Award Date | 07/03/2023 |
| Closeout Date | Not set |
| Work Description | I-105 METRO Express Lanes Project |
| Location Description | LA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6 |
| QA Service Level | 2 (Verified on 04/11/2025) |
Sample Information
| Sample Taken Date | 07/13/2026 | Sample Unique Key | 84 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/14/2026 | Sample type | Quality Assurance |
| A brief description of the sample | three quarter inch HMA Type A | The quantity of what the sample constitutes | 81.17 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Rigoberto |
| Last name of sampler or witnessed by | Arroyo | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA Irwindale | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-13-84
DIME Test ID: 2026-07-13-84-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-10-07
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Aleksey Souglobov
Date of test: 07/17/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4004.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6169.6 g
Mass of HMA Sample prior to ignition: 2164.7 g
Mass Loss: 107.7 g
Mass of aggregate remaining after ignition: 2057.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.46 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.52 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/7/2026 ✔