Summary for Test 2026-09-25-1-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001723 DEA: 050N7064 EFIS: 0524000077 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-10.9/12.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | SB 101 - Segment 4E North - Cabrillo |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 09/25/2026 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/01/2026 | Sample type | Quality Assurance |
| A brief description of the sample | #6 2'-6" welded hoops | The quantity of what the sample constitutes | 1500 welded hoops |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Johnathan |
| Last name of sampler or witnessed by | Shoulders | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | TNT Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L179-120-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4160321 |
| Hoop Manufacturer Lot Number(s) | Lots 1-10 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 2'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel AZ |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-09-25-1
DIME Test ID: 2026-09-25-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-10-07
Test Results
Number of Samples: 12
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 10/07/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 40720 | 92500 | Affected Zone | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 41410 | 94000 | Bar | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 42870 | 97500 | Bar | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 41930 | 95500 | Bar | Kleinfelder |
| 5 | 1 | 3 | 6 | 0.44 | 42120 | 95500 | Bar | Kleinfelder |
| 6 | 2 | 3 | 6 | 0.44 | 43220 | 98000 | Bar | Kleinfelder |
| 7 | 3 | 3 | 6 | 0.44 | 42300 | 96000 | Bar | Kleinfelder |
| 8 | 4 | 3 | 6 | 0.44 | 41340 | 94000 | Affected Zone | Kleinfelder |
| 9 | 1 | 8 | 6 | 0.44 | 41280 | 94000 | Affected Zone | Kleinfelder |
| 10 | 2 | 8 | 6 | 0.44 | 43700 | 99500 | Bar | Kleinfelder |
| 11 | 3 | 8 | 6 | 0.44 | 42170 | 96000 | Bar | Kleinfelder |
| 12 | 4 | 8 | 6 | 0.44 | 41410 | 94000 | Bar | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/7/2026 ✔