Summary for Test 2026-09-11-72-2
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1002539 DEA: 042X7104 EFIS: 0425000144 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL--unknown |
| Award Date | 06/09/2026 |
| Closeout Date | Not set |
| Work Description | HM1 Pavement |
| Location Description | SOLANO COUNTY NEAR DIXON ON ROUTE 80 AT PEDRICK ROAD OVERCROSSING AND ON ROUTE 113 FROM ROUTE 12 TO 0.3 MILE SOUTH OF PARKWAY BOULEVARD |
| QA Service Level | 1 (Verified on 08/11/2026) |
Sample Information
| Sample Taken Date | 09/11/2026 | Sample Unique Key | 72 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/14/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4"WMA-Rap 15% | The quantity of what the sample constitutes | 2250-3000 Tons |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Cody |
| Last name of sampler or witnessed by | Cordero | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Woodland | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 4 | HMA Mix Number | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-11-72
DIME Test ID: 2026-09-11-72-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-10-07
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Concepcion
Date of test: 09/14/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2074.7 g
Mass Loss: 119.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.75 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.87 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/7/2026 ✔