Summary for Test 2018-05-21-5-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211004
DEA: 05330784
EFIS: 0512000076
DIST-CO-RTE-PM05-SLO-46-46.0/50.2
Award Date02/10/2016
Closeout Date10/15/2019
Work DescriptionCONVERT 2-LANE TO 4 LANE EXPRESSWAY.
Location DescriptionNEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD
QA Service Level1 (Verified on 01/08/2016)

Sample Information

Sample Taken Date05/21/2018 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing05/25/2018 Sample typeQuality Assurance
A brief description of the samplesize 10 Coupler The quantity of what the sample constitutes104
From where was the sample collectedFabricator First name of sampler or witnessed byNicholas
Last name of sampler or witnessed byHeisdorf Title of samplerStructure Rep
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameGerdau
Transportation Laboratory (TL) NumberC749162 Inspector Lot Number from the Transportation Laboratory (TL) Form05-510-46
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size10 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)Z85832A, 75069594 Rebar Heat Number(s)65030696 02
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-05-21-5
DIME Test ID: 2018-05-21-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-06-06

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/29/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
132#10/32mm1.27012394097587Necking OkBrian

General comments (publicly viewable) (Max 1000 characters): Necking Ok
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/30/2018 ✔