Summary for Test 2026-08-12-80-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for storing JMF sample data |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/12/2026 | Sample Unique Key | 80 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/13/2026 | Sample type | Verification |
| A brief description of the sample | 1/2" HMA-A | The quantity of what the sample constitutes | Boxes of Mix |
| From where was the sample collected | Source | First name of sampler or witnessed by | Julian |
| Last name of sampler or witnessed by | Gonzales | Title of sampler | Not set |
| Telephone number of sampler | Not set | Laboratory sample identification | Not set |
| Linked DIME Sample ID | Not set | The fabricator/manufacturer/facility name | DSG- Marysville |
| Transportation Laboratory (TL) Number | Not set | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | Not set |
| Sublot number | Not set | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2026-08-12-80
DIME Test ID: 2026-08-12-80-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-10-02
Test Results
Number of tests: 3
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 09/28/2026
Specific Gravity for Sample 1: no data
Specific Gravity for Sample 2: no data
Specific Gravity for Sample 3: no data
Average Specific Gravity: 2.542
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): Submitted from JMF - Julian Gonzales
Test was verified on 10/2/2026 ✔