Summary for Test 2026-09-24-6-17
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 994675 DEA: 07390204 EFIS: 0722000334 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-0.4 / 2.1 |
| Award Date | 01/24/2025 |
| Closeout Date | Not set |
| Work Description | Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints. |
| Location Description | RTE 47 between Terminal Island and San Pedro PM 0.4/2.1 |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 09/24/2026 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/28/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 7/8" x 2-1/4" F3125/F1852 A325TC Bolt Assembly | The quantity of what the sample constitutes | 1710 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Johnathan |
| Last name of sampler or witnessed by | Shoulders | Title of sampler | QA |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Cordova Bolt Inc. Buena Park, CA. | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L179-118-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | W000367784 |
|---|---|---|---|
| Heat Number(s) | BOLT 1000236215 NUT 1000133998 WASHER 190264150 | Nut Mfg. Lot Number(s) | W000336977 |
| Washer Mfg. Lot Number(s) | E9470 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2.25" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | MECH GALV |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | W000367784 |
| Rocap Test Requirement(s) | YES | Lubricant Requirements(s) | YES |
| Washer Inner Diameter(s) | 94 in | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-09-24-6
DIME Test ID: 2026-09-24-6-17
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-10-08
Test Results
Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 10/02/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | W000336977 | 0.875 | 80850 | 0 | 0 | Nut Proof Load | Kleinfelder |
| 2 | 1B | W000336977 | 0.875 | 80850 | 0 | 0 | Nut Proof Load | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2026 ✔