Summary for Test 2026-09-24-6-16

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994675
DEA: 07390204
EFIS: 0722000334
DIST-CO-RTE-PM07-LA-47-0.4 / 2.1
Award Date01/24/2025
Closeout DateNot set
Work DescriptionBridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location DescriptionRTE 47 between Terminal Island and San Pedro PM 0.4/2.1
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date09/24/2026 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing09/28/2026 Sample typeQuality Assurance
A brief description of the sample7/8" x 2-1/4" F3125/F1852 A325TC Bolt Assembly The quantity of what the sample constitutes1710
From where was the sample collectedJob Site First name of sampler or witnessed byJohnathan
Last name of sampler or witnessed byShoulders Title of samplerQA
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCordova Bolt Inc. Buena Park, CA.
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL179-118-26
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)W000367784
Heat Number(s)BOLT 1000236215 NUT 1000133998 WASHER 190264150 Nut Mfg. Lot Number(s)W000336977
Washer Mfg. Lot Number(s)E9470 Bolt SpecificationASTM A325
Bolt Length(s)2.25" Nut SpecificationA563
Washer SpecificationF436 FinishMECH GALV
Diameter/Size7/8" Bolt Mfg. Lot NumberW000367784
Rocap Test Requirement(s)YES Lubricant Requirements(s)YES
Washer Inner Diameter(s)94 in Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2026-09-24-6
DIME Test ID: 2026-09-24-6-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-10-08

Test Results


Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 10/02/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AW0003677840.8756194000Bolt TensileKleinfelder
21BW0003677840.8755938000Bolt TensileKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/8/2026 ✔