Summary for Test 2026-09-29-35-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1001645
DEA: 051R1004
EFIS: 0523000125
DIST-CO-RTE-PM05-SLO, -1-32.6
Award DateNot set
Closeout DateNot set
Work DescriptionBRIDGE REPLACEMENT, HMA, AND RSP PROTECTION.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE
QA Service Level1 (Verified on 11/03/2025)

Sample Information

Sample Taken Date09/29/2026 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing09/29/2026 Sample typeAcceptance
A brief description of the sampleGravel Filter 2 Material The quantity of what the sample constitutesGravel Filter 2
From where was the sample collectedJob Site First name of sampler or witnessed byChris
Last name of sampler or witnessed byPalmer Title of samplerCT Tester
Telephone number of sampler Laboratory sample identification260929-1 Gravel Filter 2
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalPortland - Rocky Canyon
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-40-0013
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedJobsite
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-09-29-35
DIME Test ID: 2026-09-29-35-1
Testing Lab: CT D05 - Paso Robles Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-10-01

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 10/01/2026
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
22369.6 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
3091.9 grams86 %
13011.2 grams42 %
18319.5 grams18 %
21683.9 grams3 %
479.6 grams
109.5 grams2 %
174.8 grams2 %
230.3 grams2 %
287.4 grams1 %
341.8 grams1 %
386.5 grams0.6 %
General comments (publicly viewable) (Max 1000 characters): Testing Under Class 1 Permeable Material Type B Specs

Test was verified on 10/1/2026 ✔