Summary for Test 2026-09-16-33-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1001564 DEA: 030J4104 EFIS: 0319000281 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-80-33.0/44.9 |
| Award Date | 07/01/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, HMA, CLASS 2 AB, RDWY EXC, MGS, & RCP. |
| Location Description | PLACER COUNTY IN AND NEAR COLFAX FROM 0.1 MILE WEST OF ROUTE 174/80 SEPARATION TO 0.1 MILE EAST OF ALTA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 09/17/2025) |
Sample Information
| Sample Taken Date | 09/16/2026 | Sample Unique Key | 33 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/17/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4" 58-22 HMA SP RAP 25% | The quantity of what the sample constitutes | 2 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Sergio |
| Last name of sampler or witnessed by | Tostado | Title of sampler | Materials Tester |
| Telephone number of sampler | 8315884727 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Hallwood | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 2 |
| Sublot number | 12 | HMA Mix Number | 30940132416P |
| Binder content (%) | 4.5 | Virgin binder PG | |
| Design binder PG | PG 58-22 | Binder Supplier | PNW |
| RAP content (%) | 25 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-16-33
DIME Test ID: 2026-09-16-33-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-10-01
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Joshua Wilson
Date of test: 09/29/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7342 grams
Mass of oven-dry sample in air for Sample 1: 2665.1 grams
Mass of container filled with the sample and water for Sample 1: 8975 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.582
Theoretical maximum density at 25°C (77°F): 2574.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/1/2026 ✔