Summary for Test 2026-08-28-51-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000970
DEA: 031J6304
EFIS: 0321000023
DIST-CO-RTE-PM03-SAC-99-6.04/7.06
Award DateNot set
Closeout DateNot set
Work DescriptionWILLOW SLOUGH REPLACEMENT
Location DescriptionSACRAMENTO COUNTY NEAR ELK GROVE FROM 0.2 MILE NORTH OF ARNO ROAD TO 0.4 MILE SOUTH OF DILLARD ROAD
QA Service Level1 (Verified on 02/13/2025)

Sample Information

Sample Taken Date08/28/2026 Sample Unique Key51
Date that the sample was received by the laboratory/organization performing the testing08/28/2026 Sample typeQuality Control
A brief description of the sampleConcrete The quantity of what the sample constitutes100 cy
From where was the sample collectedJob Site First name of sampler or witnessed byFikra
Last name of sampler or witnessed byJahya Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameFolsom Ready Mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberC62A4D1
The truck number from where the sample was collected97 The batch plant ticket number from where the sample was collected1298324
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-08-28-51
DIME Test ID: 2026-08-28-51-5
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-30

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 09/25/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 130944 lb
Maximum load on cylinder 2: 123910 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4520 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/30/2026 ✔