Summary for Test 2026-07-09-123-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 1001169 DEA: 07314524 EFIS: 0722000300 COOP: 075283 |
|---|---|
| DIST-CO-RTE-PM | 07--- |
| Award Date | 07/03/2023 |
| Closeout Date | Not set |
| Work Description | I-105 METRO Express Lanes Project |
| Location Description | LA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6 |
| QA Service Level | 2 (Verified on 04/11/2025) |
Sample Information
| Sample Taken Date | 07/09/2026 | Sample Unique Key | 123 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/10/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 Cold feed | The quantity of what the sample constitutes | 122.06 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Rigoberto |
| Last name of sampler or witnessed by | Arroyo | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | All American Asphalt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-005 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | HMA Plant Cold Feed | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-07-09-123
DIME Test ID: 2026-07-09-123-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2026-09-30
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: SoCal Reports
Date of test: 07/15/2026
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| 0 % | ||||||
| 0 % | ||||||
| 0 % | ||||||
| 96 % | ||||||
| 85 % | ||||||
| 74 % | ||||||
| 55 % | ||||||
| 63 % | ||||||
| 41 % | ||||||
| 28 % | ||||||
| 19 % | ||||||
| 12 % | ||||||
| 5 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/30/2026 ✔