Summary for Test 2026-09-09-64-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 995228
DEA: 07347904
EFIS: 0718000123
DIST-CO-RTE-PM07-LA-405-31.2/41.4
Award Date03/07/2025
Closeout DateNot set
Work DescriptionCOLD PLANE, PLACE HMA, RHMA, JPCP, ISR, & REPLACE BRIDGE SLABS.
Location DescriptionLOS ANGELES FROM WILSHIRE BOULEVARD UNDERCROSSING TO VICTORY BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 01/22/2024)

Sample Information

Sample Taken Date09/09/2026 Sample Unique Key64
Date that the sample was received by the laboratory/organization performing the testing09/16/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byVICTOR
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-09-09-64
DIME Test ID: 2026-09-09-64-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-10-09

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 09/29/2026
Time of test: 8:47 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 64.3 %
Viscosity reading #1 (A) : 0.318 Pa-s
Viscosity reading #2 (B) : 0.322 Pa-s
Viscosity reading #3 (C): 0.325 Pa-s
Average viscosity: 0.322 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/9/2026 ✔