Summary for Test 2026-09-22-44-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 995494 DEA: 081K4904 EFIS: 0819000050 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R105.1/R105.9 |
| Award Date | 05/28/2024 |
| Closeout Date | Not set |
| Work Description | BUILDING WORK, HMA, AND TEMPORARY PORTABLE SANITARY FACILITIES. |
| Location Description | SAN BERNARDINO COUNTY ABOUT 36 MILES WEST OF NEEDLES FROM 2.1 MILES TO 1.3 MILES WEST OF GOFFS ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 01/18/2024) |
Sample Information
| Sample Taken Date | 09/22/2026 | Sample Unique Key | 44 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/24/2026 | Sample type | Acceptance |
| A brief description of the sample | RWMA | The quantity of what the sample constitutes | 163.96 tons |
| From where was the sample collected | Source | First name of sampler or witnessed by | Luke |
| Last name of sampler or witnessed by | Hall | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-22-44
DIME Test ID: 2026-09-22-44-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-29
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 09/28/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2161.0 g
Mass Loss: 155.0 g
Correction Factor (Percent by mass of HMA Specimen): -0.01 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.06 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 7.12 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/29/2026 ✔